Purpose

Recover the password for the supervisor or operator mode.


Problem Explanation/Objective

To add a level of security to the OS32C users are able to change the password on the equipment to protect the code and program from any changes. In case they lose the information of the password they will need to follow the steps on this document for us to work with the data and share the password.


Supported devices

  • OS32C Series


Requirements

  • OS32C Series
  • Password recovery tool (Can be found on the OS32C Software "OS32C Configuration Tool")


Procedure

1.Connect to the OS32C.

2.Log on with the Operator access level (No password needed)

3.From the Utilities menu, select Read Encrypted Password.

4.Select Maintenance or Supervisor and click Read Password.

5.An encrypted password will show on the screen and the client will need to get in touch with TSG and share that information.

6.Contact ia.techsupport@omron.com and send the encrypted password.

7.A Safety TSG agent will send the password and will explain to what level of access it corresponds.



Date/Revision History

First review 12/09/2024 V1.0

2nd review 01/22/2025 V1.1


Author:

Diego Roses, Technical Support Engineer


References

OS32C Manual - https://assets.omron.com/m/4128822e4e8a9131/original/OS32C-Series-Safety-Laser-Scanner-User-s-Manual.pdf